Inert Atmosphere
Bench Furnaces

BULLETIN
BF-720

INERT
ATMOSPHERE
ELECTRIC
HEAT TREATING
FURNACES


Grieve standard Inert Atmosphere Bench Furnaces are specifically designed for heat treating applications requiring inert atmosphere protection. Inert atmospheres protect the work from oxidation even while being subjected to high temperatures. Five sizes to 2.0 cubic feet with temperatures to 2200°F. Precision microprocessor based temperature controls and energy-saving insulation maximize the cost efficiency and performance of these rugged units. Ideal for heat treating of tools, dies and other parts.


Standard Features
Specifications
Standard Equipment
Additional Equipment
MODEL BAF-121212-HT
WITH OPTIONAL INERT ATMOSPHERE INLET PIPING
MODEL BAF-122412
WITH OPTIONAL FLOOR STAND
AND INERT ATMOSPHERE INLET PIPING

STANDARD FEATURES  Back to Top


SPECIFICATIONS  Back to Top
NOT FOR USE WITH FLAMMABLE SOLVENTS, VAPORS OR GASES.
Model
Work Space
Outside
Dimensions
(WxDxH)
Max
Temp*
Insu-
lation
Height
w/Door
Open
Heat Input
KW
Operating Characteristics†
Approx
Shipping
Weight
Model
Dimensions
(WxDxH)
Volume
Cu Ft
230V
460V
Control
Accuracy
Furnace
Uniformity
Rise Time
230V 460V
BAF-8128 8" x 12" x 8" 0.44 24" x 31" x 31" 2000°F 5" 52" 4.5 6 ± 0.3% ±15°F 65 min 50 min 420 lbs BAF-8128
BAF-8128-HT 8" x 12" x 8" 0.44 26" x 33" x 33" 2200°F 6" 54" 4.5 6 ± 0.3% ±20°F 75 min 55 min 505 lbs BAF-8128-HT
BAF-12128 12" x 12" x 8" 0.67 28" x 31" x 31" 2000°F 5" 52" 6 8 ± 0.3% ±15°F 55 min 45 min 470 lbs BAF-12128
BAF-12128-HT 12" x 12" x 8" 0.67 30" x 33" x 33" 2200°F 6" 54" 6 8 ± 0.3% ±20°F 80 min 60 min 550 lbs BAF-12128-HT
BAF-121212 12" x 12" x 12" 1.0 28" x 31" x 37" 2000°F 5" 66" 7.5 10 ± 0.3% ±12°F 50 min 40 min 520 lbs BAF-121212
BAF-121212-HT 12" x 12" x 12" 1.0 30" x 33" x 39" 2200°F 6" 68" 7.5 10 ± 0.3% ±17°F 65 min 50 min 620 lbs BAF-121212-HT
BAF-12188 12" x 18" x 8" 1.0 28" x 37" x 31" 2000°F 5" 52" 7.5 10 ± 0.3% ±10°F 65 min 50 min 545 lbs BAF-12188
BAF-12188-HT 12" x 18" x 8" 1.0 30" x 39" x 33" 2200°F 6" 54" 7.5 10 ± 0.3% ±15°F 75 min 55 min 645 lbs BAF-12188-HT
BAF-121812 12" x 18" x 12" 1.5 28" x 37" x 37" 2000°F 5" 66" 12 16 ± 0.3% ±10°F 45 min 35 min 570 lbs BAF-121812
BAF-121812-HT 12" x 18" x 12" 1.5 30" x 39" x 39" 2200°F 6" 68" 12 16 ± 0.3% ±15°F 60 min 45 min 675 lbs BAF-121812-HT
BAF-12248 12" x 24" x 8" 1.33 28" x 43" x 31" 2000°F 5" 52" 12 16 ± 0.3% ±10°F 50 min 40 min 680 lbs BAF-12248
BAF-12248-HT 12" x 24" x 8" 1.33 30" x 45" x 33" 2200°F 6" 54" 12 16 ± 0.3% ±15°F 60 min 45 min 755 lbs BAF-12248-HT
BAF-122412 12" x 24" x 12" 2.0 28" x 43" x 37" 2000°F 5" 66" 15 20 ± 0.3% ±10°F 45 min 35 min 775 lbs BAF-122412
BAF-122412-HT 12" x 24" x 12" 2.0 30" x 45" x 39" 2200°F 6" 68" 15 20 ± 0.3% ±15°F 60 min 45 min 850 lbs BAF-122412-HT
*1950°F for continuous operation under Nitrogen atmosphere. For
operation at higher temperatures, furnace must be periodically run with
air atmosphere to buildup protective oxide coating on heating elements.
†Accuracy as percent of controller span. Uniformity at 100°F below maximum
temperature. Rise Time in minutes to 100°F below maximum temperature.
Tests run with empty furnace and minimum exhaust. Performance will vary with
load and application. See Bulletin TC-920 for additional details.


STANDARD EQUIPMENT  Back to Top

  • Standard Electrical Characteristics
    — 208 volts, 1 or 3-phase, 50/60 Hz
    — 230 volts, 1 or 3-phase, 50/60 Hz
    — 460 volts, 3-phase, 50/60 Hz
    — Other electrical characteristics available

    Each furnace features completely wired control panel, located under the furnace, enclosing terminals for incoming power, temperature controller, heating element control contactor, excess temperature controller, separate contactor interlocked with excess temperature controller, 115 volt control circuit transformer, on-off heat switch and red pilot light. Door interlock switch turns off power to heating elements when door is opened. High temperature enamel painted aluminized steel exterior.
    Ceramic hearth tray rated for 60 lbs distributed loading. Atmosphere inlet (1/2" NPT) at side of work space and atmosphere outlet (3/4" NPT) through the top at back. Sealed rear terminal box with vent petcock.


  • Cross section through work space
    (Front View)




    ADDITIONAL EQUIPMENT AVAILABLE  Back to Top
    See Bulletin TC-960 for modifications and other optional equipment.

    • Inert Atmosphere Inlet Piping, complete with indicating flow control and gas valve. Specify atmosphere
      Option IAIP

    • Quench Tank, carbon steel, 40 gallon capacity, 12" x 20" x 12" deep work basket, subway grating basket support, 1/2 HP direct driven mixer, 23” x 23” x 44” high overall, for 115 or 230/1/60
      Option QT


    • Quench Tank Electric Heater, with temperature control
      Option QTH

    Bench Furnaces