High Temperature
Inert Atmosphere Ovens

BULLETIN
CA-480

1000°F AND 1250°F
FRONT-TO-BACK
HORIZONTAL AIR FLOW
INERT ATMOSPHERE OVENS


Inert atmosphere ovens for operation at up to 1250°F. Protect parts from oxidation using any non-flammable gas such as Nitrogen, Argon or Carbon Dioxide. Front-to-back horizontal air flow completely surrounds work on shelves or large parts placed directly on the optional reinforced work space bottom. Includes cooling jacket which can be equipped with optional cooling blower and automatic dampers. Installation of optional atmosphere purge solenoid, cooling blower and programmable temperature controller provides completely automatic sequencing.


Standard Features
Specifications
Standard Equipment
Additional Equipment
MODEL ID-1250 WITH OPTIONAL 16" INTEGRAL OVEN LEGS

STANDARD FEATURES  Back to Top

  • UL LISTED CONTROL PANEL
  • Standard Inert Atmosphere Ovens from Grieve meet the requirements of National Fire Protection Association Standard 86, Industrial Risk Insurers, Factory Mutual and OSHA standards. For some applications, such as those involving hazardous locations, the above organizations require additional safety devices.

  • Controls
    —Digital, microprocessor based, thermocouple actuated, indicating temperature controller
    —Motor control push buttons
    —On-off heat switch
    —Easy-to-see pilot lights

  • Safety Equipment
    —Adjustable, thermocouple actuated, manual reset excess temperature controller
    —Separate heating element control contactors
    —Recirculating blower air flow safety switch

  • Construction
    —All interior seams welded gas-tight
    —All wall penetrations welded at inside and fitted with compression fitting at outside of oven
    —Silicone rubber atmosphere seal at outside perimeter of oven door
    —High temperature inner door gasket with stainless steel spring insert to seal heat in oven and protect atmosphere seal
    —2-point cam action positive latching door hardware
    —Adjustable offset door hinges to guarantee tight closure of door seal
    —Exterior blower shaft seal
    —Inert atmosphere inlet with pressure regulator to maintain positive pressure within oven
    —0-200 CFH atmosphere flow meter
    —Pressure gauge to indicate interior oven pressure
    —Inert atmosphere outlet with pressure relief
    —Air jacket on inner oven for cooling
    —Front-to-back horizontal air flow
    —16 gauge 304 stainless steel interior
    —Aluminized steel exterior with enamel finish
    —Brushed stainless steel control panel face
    —Insulated with 2" thick 1900°F insulating block, backed up with 10 lbs/cf density industrial rockwool
    —Built-in baffles prevent radiant heat
    —Two (2) stainless steel wire shelves
    —Channel shelf supports prevent shelves tipping
    —1 year limited warranty

  • Every oven fully assembled and individually factory tested


    SPECIFICATIONS  Back to Top
    NOT FOR USE WITH FLAMMABLE SOLVENTS, VAPORS OR GASES.
    Model
    Work Space
    Outside
    Dimensions*
    (WxDxH)
    Max
    Temp
    Blower
    Insu-
    lation
    Doors
    KW
    Operating Characteristics†
    Approx
    Shipping
    Weight
    Model
    Dimensions
    (WxDxH)
    Volume
    Cu Ft
    CFM HP Control
    Accuracy
    Oven
    Uniformity
    Rise Time
    IA-1000 24" x 24" x 24" 8 49" x 56" x 43.5" 1000°F 600 1/2 8" Single 12 ±0.3% ±10°F 80 min 2260 lbs IA-1000
    IA-1250 24" x 24" x 24" 8 53" x 60" x 47.5" 1250°F 1000 3/4 10" Single 18 ±0.3% ±13°F 90 min 2600 lbs IA-1250
    IB-1000 24" x 36" x 24" 12 49" x 68" x 43.5" 1000°F 1000 3/4 8" Single 12 ±0.3% ±10°F 100 min 2530 lbs IB-1000
    IB-1250 24" x 36" x 24" 12 53" x 72" x 47.5" 1250°F 1200 1 10" Single 18 ±0.3% ±13°F 111 min 3020 lbs IB-1250
    IC-1000 36" x 36" x 36" 27 61" x 66" x 55.5" 1000°F 1000 3/4 8" Single 18 ±0.3% ±10°F 115 min 3200 lbs IC-1000
    IC-1250 36" x 36" x 36" 27 65" x 70" x 59.5" 1250°F 1200 1 10" Single 24 ±0.3% ±13°F 129 min 3930 lbs IC-1250
    ID-1000 36" x 48" x 36" 36 61" x 78" x 55.5" 1000°F 1200 1 8" Single 18 ±0.3% ±10°F 140 min 4100 lbs ID-1000
    ID-1250 36" x 48" x 36" 36 65" x 82" x 59.5" 1250°F 1400 1-1/2 10" Single 24 ±0.3% ±13°F 170 min 4500 lbs ID-1250
    *All Models—Control panel extends 13" above.
    Blower motor overhang 18" rear.
    †Accuracy as percent of controller span. Uniformity at 100°F below maximum temperature. Rise Time in minutes to 100°F below maximum temperature. Tests run with empty oven and minimum exhaust. Performance will vary with load and application. See Bulletin TC-920 for additional details.

    STANDARD EQUIPMENT  Back to Top
    — 208 volts, 3-phase, 60 Hz
    — 230 volts, 3-phase, 60 Hz
    — 460 volts, 3-phase, 60 Hz
    — Other electrical characteristics available

    Each features completely wired, top access UL listed control panel enclosing terminals for incoming power, temperature controllers, push buttons and pilot lights. Motor starter and heating element contactors electrically interlocked to shut off heaters if power to blower is interrupted and to permit operation of blower without heat for cooling. Incoloy sheathed tubular heating elements. The 1250°F models have a heat chamber high limit controller.

    Two (2) reinforced 100 lbs uniformly distributed load capacity, stainless steel wire shelves. Models IA and IB will hold seven(7) shelves on 3" centers; models IC and ID five(5) shelves on 6" centers.

    Trilite Green enamel painted aluminized steel exterior. Insulated with 2" of 1900°F insulating block backed up with 1250°F industrial rockwool.

    Inert atmosphere is introduced at blower shaft (1/2" NPT) and positive oven pressure maintained by inlet pressure regulator. Atmosphere flow indicated on 0-200 CFH flow meter. Oven pressure indicated on 0-5 inch water column pressure gauge. Continuously welded inner oven construction with compression fittings at wall penetrations maintains atmosphere integrity. Atmosphere outlet equipped with pressure relief which can be manually opened to increase inert gas flow for initial purge of air from oven. Adjustable positive latching door hardware and offset hinges assure positive door seal. The inner high temperature gasket seals directly against the door plug; outer atmosphere gasket seals against the front face of the oven.

    Circulation Diagram
    (Top View)


    ADDITIONAL EQUIPMENT AVAILABLE  Back to Top See Bulletin TC-960 for modifications and other optional equipment.