High Temperature |
![]() |
BULLETIN WI-520
HEAVY DUTY |
| Standard Features Specifications Standard Equipment |
![]() |
![]() |
![]() |
![]() |
![]() |
| MODEL B1-1000
ELECTRIC WITH OPTIONAL TRUCK TRACKS AND RECORDING THERMOMETER |
MODEL B4-1000
GAS WITH STANDARD MODULATING BURNER SYSTEM AND OPTIONAL TRUCK TRACKS AND RECORDING THERMOMETER |
STANDARD
FEATURES Back to Top
LISTED CONTROL
PANEL
Digital, microprocessor based, thermocouple actuated, indicating temperature
controller
Modulating burner on gas-fired ovens
Motor control push buttons and on-off heat switch
Easy-to-see pilot lights
Adjustable, thermocouple actuated, manual reset excess temperature controller
Separate heating element control contactors
Recirculating blower air flow safety switch
Adjustable, thermocouple actuated, manual reset excess temperature controller
Electronic flame safeguard protection
Powered forced exhauster for combustion venting
Exhauster air flow safety switch
Recirculating blower air flow safety switch
Purge timer
High gas pressure switch
Low gas pressure switch
Two pilot safety shutoff valves with leak test stations
Two main safety shutoff valves with leak test stations (Industrial Risks Insurers vent valve only provided on specific request)
Valve position indicator on main safety shutoff valves
Over 400,000 BTU/HR safety shutoff valve interlocked with purge timer
Choice of air flow patterns
Adjustable patented opposed louvers on full coverage supply and return
ductwork
Exceptionally heavy duty doors
Explosion venting latches
Doors equipped with expansion joints on inner face to guarantee uniform
sealing at all temperatures
Inner and outer door gaskets; inner gasket seals directly against door
plug; outer gasket seals against front face of oven
3/8" steel plate oven front to guarantee rigid sealing surface at all
temperatures
Slip flashing at door openings to allow inner oven to expand without
effecting outer oven or door sealing surface
Aluminized steel exterior with enamel finish
Brushed stainless steel control panel face
1 year limited warranty
SPECIFICATIONS Back
to Top
CAUTION: OVENS PROCESSING
COMBUSTIBLE MATERIAL ARE REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION STANDARD
86 TO HAVE A FIRE SUPPRESSION SYSTEM. IF FLAMMABLE SOLVENTS OR VAPORS ARE PRESENT
IN AN OVEN, OSHA REQUIRES CONFORMANCE WITH NFPA 86 WHICH DEFINES OVENS FOR THESE
APPLICATIONS AS CLASS A OVENS. A POWERED FORCED EXHAUSTER AND OTHER NON-STANDARD
SAFETY EQUIPMENT MUST BE ADDED. SEE BULLETIN TC-940
AND CONSULT FACTORY.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| *All ModelsControl panel
overhang 9" right side. Blower motor overhang on rear: 19" on 3 and 5 HP motors, 26" on 7-1/2 and 10 HP motors, 28" on 15 HP. Gas ModelsBurner overhang 15" right side. |
Accuracy as percent of controller span. Uniformity at 100°F below maximum temperature. Rise Time in minutes to 100°F below maximum temperature. Tests run with empty oven and minimum exhaust. Performance will vary with load and application. See Bulletin TC-920 for additional details. |
STANDARD
EQUIPMENT Back to Top
|
Circulation Diagram (Front View) |
||
|
|
|
|
B1, B2, B3, B4 Series Combination vertical and horizontal air flow. |
B1H, B2H, B3H, B4H Series Full horizontal air flow. |
|
| Walk-In
Oven Additional Equipment |