Class 100 |
![]() |
BULLETIN WI-462
CLASS 100 |
For truck processing where
eliminating particle contamination is required. Applications include sterilization,
depyrogenation, curing and drying. These electrically heated ovens come in five
sizes with features to provide a low particle count Class 100 atmosphere inside.
Operating temperatures to 500°F with work space volumes ranging from 57.8
to 163.6 cubic feet. Exterior construction minimizes particle generation. Heavy
| Standard Features Specifications Standard Equipment Additional Equipment |
![]() |
![]() |
![]() |
![]() |
![]() |
| MODEL TLA-500 WITH OPTIONAL PROGRAMMABLE RECORDING TEMPERATURE CONTROLLER, STAINLESS STEEL EXTERIOR, DOOR LOCK, FRESH AIR AND EXHAUST FILTERS, PRESSURIZING BLOWER, PRESSURE GAUGES, TRUCK AND TRANFER DOLLY | |
STANDARD
FEATURES Back to Top
UL LISTED CONTROL
PANEL
Digital, microprocessor based, thermocouple actuated, indicating temperature controller
Solid state heating element relay
Motor control push buttons and on-off heat switch
Easy-to-see pilot lights
Adjustable, thermocouple actuated, manual reset excess temperature controller
Separate heating element control contactors
Recirculating blower air flow safety switch
Recirculation HEPA filter, stainless steel, high temperature, 99.97% efficient on 0.3 micron particles
Stainless steel recirculating blower
Silicone rubber blower shaft seal
Stainless steel interior type 304, 2B finish
Continuously back-welded seams on oven interior
Easy to remove interior duct work for cleaning
Incoloy sheathed tubular heating elements
D.O.P. test port upstream of HEPA filters
Positive latching door hardware
Silicone rubber door seal
Sealed penetrations for heaters and thermocouples
Adjustable fresh air inlet optional HEPA filter with prefilter available
Adjustable exhaust outlet optional HEPA filter available
Insulated floor with removable truck wheel guides
Brushed stainless steel control panel face and door cover
Aluminized steel exterior with white epoxy paint optional brushed stainless steel exterior available
1 year limited warranty
SPECIFICATIONS Back
to Top
CAUTION: OVENS PROCESSING
COMBUSTIBLE MATERIAL ARE REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION STANDARD
86 TO HAVE A FIRE SUPPRESSION SYSTEM. IF FLAMMABLE SOLVENTS OR VAPORS ARE PRESENT
IN AN OVEN, OSHA REQUIRES CONFORMANCE WITH NFPA 86 WHICH DEFINES OVENS FOR THESE
APPLICATIONS AS CLASS A OVENS. A POWERED FORCED EXHAUSTER AND OTHER NON-STANDARD
SAFETY EQUIPMENT MUST BE ADDED. SEE BULLETIN TC-940
AND CONSULT FACTORY.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Accuracy as percent of controller span. Uniformity at 50°F below maximum temperature. Rise Time in minutes to 50°F below maximum temperature. Tests run with empty oven and minimum exhaust. Performance will vary with load and application. See Bulletin TC-920 for additional details. |
STANDARD
EQUIPMENT Back to Top
208 volts, 3-phase, 60 Hz
230 volts, 3-phase, 60 Hz
460 volts, 3-phase, 60 Hz
Other electrical characteristics available
These Class 100 ovens come in five sizes and include insulated floors with removable
truck wheel guide tracks. They feature full horizontal air flow and adjustable
patented opposed louvers on full coverage supply and return duct work. Easily
removable
interior duct work for cleaning.
Each features completely wired, side access
UL
listed control panel enclosing terminals for incoming power, temperature controllers,
push buttons and pilot lights. Motor starter and solid state heating element
relay electrically interlocked to shut off heaters if power to blower is interrupted
and to permit operation of blower without heat for cooling. Incoloy sheathed
tubular heating elements. Exhaust outlet 4" diameter.
Stainless steel (type 304, 2B finish) interior with continuously back-welded
seams. Recirculated air flow is continuously passed through high temperature
HEPA filters to remove particles. High temperature HEPA filters have stainless
steel housing and are 99.97% efficient on 0.3 micron particles.
Mechanical enclosure covers recirculating blower motor, heating element terminal
box, air flow safety switch and other components to provide continuous exterior
surface for easy cleaning.
Outer door cover and control panel face constructed from #4 brushed finish,
type 304 stainless steel. Aluminized steel exterior finished with white epoxy
enamel paint.
Optional loading trucks hold nine(9) shelves on 6" vertical centers and are
all welded stainless steel construction including stainless steel casters. Loading
trucks are moved to and from oven on optional transfer dollies.
( Front View ) ![]() Heated air is forced through HEPA filters prior to entering work space and then passes between truck shelves and across parts. |
ADDITIONAL
EQUIPMENT AVAILABLE Back to Top See
Bulletin TC-960 for modifications and other
optional equipment.
|
| Stainless steel shelves rated 100
lbs uniformly distributed. Models TLD-500 and TLE-500 hold two trucks front to rear. |
| Class 100 Clean Room Cabinet Ovens |