Class 100 |
![]() |
BULLETIN CA-460
CLASS 100 |
| Standard Features Specifications Standard Equipment Additional Equipment |
![]() |
![]() |
![]() |
![]() |
![]() |
| CLB-500 WITH SAFETY EQUIPMENT FOR HANDLING FLAMMABLE SOLVENTS - SEE BULLETIN TC-940 |
MODEL
CLD-500 WITH OPTIONAL PROGRAMMABLE TEMPERATURE CONTROLLER |
STANDARD FEATURES Back to Top
UL LISTED CONTROL
PANEL
Digital, microprocessor based, thermocouple actuated, indicating temperature
controller
Solid state heating element relay
Motor control push buttons and on-off heat switch
Easy-to-see pilot lights
Adjustable, thermocouple actuated, manual reset excess temperature controller
Separate heating element control contactors
Recirculating blower air flow safety switch
Recirculation HEPA filter, stainless steel, high temperature, 99.97%
efficient on 0.3 micron particles
Direct driven stainless steel recirculating blower
Silicone rubber blower shaft seal
Stainless steel interior type 304, 2B finish
Continuously back-welded seams on oven interior
Easy to remove interior duct work for cleaning
Incoloy sheathed tubular heating elements
D.O.P. test port upstream of HEPA filter
Positive latching door hardware
Silicone rubber door seal
Sealed penetrations for heaters and thermocouples
Adjustable fresh air inlet optional HEPA filter with prefilter available
Adjustable exhaust outlet optional HEPA filter available
Two (2) stainless steel shelves
Channel shelf supports prevent shelves tipping
Brushed stainless steel control panel face and door cover
Aluminized steel exterior with white epoxy paint optional brushed
stainless steel exterior available
1 year limited warranty
SPECIFICATIONS Back to Top
CAUTION: OVENS
PROCESSING COMBUSTIBLE MATERIAL ARE REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION
STANDARD 86 TO HAVE A FIRE SUPPRESSION SYSTEM. IF FLAMMABLE SOLVENTS OR VAPORS
ARE PRESENT IN AN OVEN, OSHA REQUIRES CONFORMANCE WITH NFPA 86 WHICH DEFINES
OVENS FOR THESE APPLICATIONS AS CLASS A OVENS. A POWERED FORCED EXHAUSTER
AND OTHER NONSTANDARD SAFETY EQUIPMENT MUST BE ADDED. SEE BULLETIN TC-940
AND CONSULT FACTORY.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| *Model CLE-500 utilizes two
(2) filters. Width increases 6" if recording instrument is installed. |
Accuracy as percent of controller span. Uniformity at 50°F below maximum temperature. Rise Time in minutes to 50°F below maximum temperature. Tests run with empty oven and minimum exhaust. Performance will vary with load and application. See Bulletin TC-920 for additional details. |
|
|
5.0 cubic feet, holds 4 shelves
|
|
|
13.5 cubic feet, holds 8 shelves
|
|
|
20.7 cubic feet, holds 8 shelves
|
|
|
29.3 cubic feet, holds 12 shelves
|
|
|
38.3 cubic feet, holds 16 shelves
|
They feature full horizontal air flow and adjustable patented opposed louvers
on full coverage supply and return duct work. Stainless steel (type 304,
2B finish) interior with continuously back-welded seams and easily removable
interior duct work for cleaning. Recirculated air flow is continuously passed
through a high temperature HEPA filter to remove particles. High temperature
HEPA filter has stainless steel housing and is 99.97% efficient on 0.3 micron
particles.
Each features completely wired, side access
UL
listed control panel enclosing terminals for incoming power, temperature
controllers, push buttons and pilot lights. Motor starter and solid state
heating element relay electrically interlocked to shut off heaters if power
to blower is interrupted and to permit operation of blower without heat
for cooling. Incoloy sheathed tubular heating elements. Exhaust outlet 4"
diameter.
Mechanical enclosure covers recirculating blower motor, heating element
terminal box, air flow safety switch and other components to provide continuous
exterior surface for easy cleaning.
Outer door cover and control panel face constructed from #4 brushed finish,
type 304 stainless steel. Aluminized steel exterior finished with white
epoxy enamel paint.
Two (2) reinforced 100 lbs uniformly distributed load capacity stainless
steel shelves; shelf support channels on 3" centers.
( Front View ) ![]() Heated air is forced through HEPA filter prior to entering work space and then passes between shelves and across parts. |
ADDITIONAL
EQUIPMENT AVAILABLE Back
to Top See Bulletin
TC-960 for modifications and other optional
equipment.
| Class 100 Clean Room Bench Ovens |