Horizontal Air Flow |
![]() |
BULLETIN CA-400 HEAVY DUTY |
| Standard Features Specifications Standard Equipment Additional Equipment |
![]() |
![]() |
![]() |
![]() |
![]() |
|
MODEL HA-650
GAS |
MODEL HC-850 ELECTRIC |
STANDARD
FEATURES Back to Top
UL LISTED CONTROL
PANEL
Digital, microprocessor based, thermocouple actuated, indicating temperature
controller
Modulating burner on gas ovens
Motor control push buttons and on-off heat switch
Easy to see pilot lights
Adjustable, thermocouple actuated, manual reset excess temperature controller
Separate heating element control contactors
Recirculating blower air flow safety switch
Adjustable, thermocouple actuated, manual reset excess temperature controller
Electronic flame safeguard protection
325 CFM powered forced exhauster for combustion venting
Exhauster air flow safety switch
Recirculating blower air flow safety switch
Purge timer
High gas pressure switch
Low gas pressure switch
Two pilot safety shutoff valves with leak test stations
Two main safety shutoff valves with leak test stations
Valve position indicator on main safety shutoff valves
Adjustable patented opposed louvers on full coverage supply and return
duct work
304 stainless steel interior
Aluminized steel exterior with enamel finish
Brushed stainless steel control panel face
Built-in baffles prevent radiant heat
Exceptionally heavy duty doors and door frame with explosion venting
latches
High temperature door gasket with stainless steel spring insert
Two (2) nickel plated wire shelves
Channel shelf supports prevent shelves tipping
Adjustable fresh air intake and exhaust dampers
High pressure recirculating blower
All welded construction
10 lbs/cf density industrial rockwool insulation
1 year limited warranty
SPECIFICATIONS Back
to Top
CAUTION: OVENS PROCESSING
COMBUSTIBLE MATERIAL ARE REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION STANDARD
86 TO HAVE A FIRE SUPPRESSION SYSTEM. IF FLAMMABLE SOLVENTS OR VAPORS ARE PRESENT
IN AN OVEN, OSHA REQUIRES CONFORMANCE WITH NFPA 86 WHICH DEFINES OVENS FOR THESE
APPLICATIONS AS CLASS A OVENS. A POWERED FORCED EXHAUSTER AND OTHER NONSTANDARD
SAFETY EQUIPMENT MUST BE ADDED. SEE BULLETIN TC-940
AND CONSULT FACTORY.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| *All ModelsControl
panel overhang 9" right side. Blower motor overhang 10" right side, except HB-850 & HY
Series 14" and HC Series 19". Gas ModelsBurner overhang 11" left side. |
Accuracy as percent of controller span. Uniformity at 50°F below maximum temperature. Rise Time in minutes to 50°F below maximum temperature. Tests run with empty oven and minimum exhaust. Performance will vary with load and application. See Bulletin TC-920 for additional details. |
STANDARD
EQUIPMENT Back to Top
208 volts, 3-phase, 60 Hz
230 volts, 3-phase, 60 Hz
460 volts, 3-phase, 60 Hz
Two (2) reinforced 200 lbs uniformly distributed load capacity, nickel plated
wire shelves; shelf support channels on 3" centers (6" on HC Series).
304 stainless steel interior with carbon steel blower and plated hardware.
Trilite
Green
enamel
painted
aluminized
steel
exterior.
These electric or gas models come in five sizes. They feature full horizontal
air flow for shelf processing at temperatures to 850°F.
Commonly used where work is shelf loaded and least restriction to free air passage
is in the horizontal direction.
Each features completely wired, side access
UL
listed control panel enclosing terminals for incoming power, temperature controllers,
push buttons and pilot lights. Motor starter and heating element contactors
electrically interlocked to shut off heaters if power to blower is interrupted
and to permit operation of blower without heat for cooling. Alloy wire heating
elements on 500°F models; incoloy sheathed tubular heating elements on
650°F and 850°F models. Exhaust outlet 4" diameter.
1,000 BTU natural gas at 6" water column pressure, 1" NPT inlet
Other gas characteristics available
Control panel as detailed above and safety devices as listed on the front of
this bulletin. Automatic pre-ignition purge period and push button electric
ignition contributes to ease of operation. Modulating gas burner is protected
with electronic flame
safety relay.
|
Circulation
Diagram
Heated air blown sideways between shelves and across parts |
|
| Gas ovens include 325 CFM exhauster. Electric ovens may require additional heat input. 500°F Models only |
| High Temperature Universal Ovens |