Printer Friendly
MODIFIED MODEL WTH566-500, Serial No.
411544
-workspace dimensions: 54" wide x 72" deep x 72" high
-30 KW installed in Incoloy sheathed tubular heating elements
-6000 CFM, 5 HP recirculating blower providing horizontal airflow
-4" thick insulated walls
-removable top mounted heat chamber
-ovenbody split into three (3) sections to fit 52" wide x 90" deep x 94" high elevator
-aluminized steel exterior
-type 304, 2B finish stainless steel interior with continuously front welded seams
-cellular silicone rubber door gasket
-stainless steel water cooling coil located in heat chamber
-digital programming temperature controller
-manual reset excess temperature controller with separate contactors
-recirculating blower air flow safety switch
-YEW micro R1800 6" strip chart recorder
-SCR power controller
-2" insulated floor with truck wheel guide tracks
|