-workspace dimensions: 300" wide x 12" deep x 18" high -34.8 KW installed in Nichrome wire heating elements -6000 CFM, total from two (2) 3-HP recirculating blower providing horizontal front to rear airflow -4” insulated walls -aluminized steel interior and exterior -reinforced 1/4” steel plate workspace floor to hold 5000 lbs. distributed load -motor operated rear hinged door -oven supported on eight (8) swivel casters with swivel locks and brakes -digital indicating temperature controller -manual reset excess temperature controller with separate contactors -recirculating blower air flow safety switch |
|
||||||||