-maximum operating temperature: 750°F -work space dimensions: 42" wide x 12' deep x 12" high -4' long open belt loading zone -1' long insulated, unheated entrance vestibule -12' long insulated heat zone with recirculated airflow -1' long open zone -2' long cooling zone -2' long open unloading zone -800,000 BTU/HR installed in modulating natural gas burner -36" wide, 1" x 1" flatwire conveyor belt with 1/2 HP motor drive, variable from 0.7 to 14.3 inches per minute -7800 CFM, 5 HP recirculating blower providing vertical downward airflow -6" insulated walls -two (2) 12" diameter tubeaxial fans, each driven by 1/2 HP motor, to push/pull air thruogh cooling zone -aluminized steel interior and exterior -safety equipment required by IRI, FM and National Fire ProtectioN Association Standard 86 for gas heated equipment including 650 CFM 1/2 HP powered forced exhauster
|
|
||||||||